Pressure reducer RDP

Sealed with check valve
Maximum service pressure: 400 bar

Operating principle

The function of the pressure reducer is to maintain constant receiver side pressure (secondary circuit) in spite of a higher variable input pressure (primary circuit). This model is made up of a valve that is leak-free when it is closed (no need for draining oil port). When the primary pressure level at P is less than the secondary pressure at A, reversed flow from A to P for the valve (which is then open) is possible.

Print this sheet
Pressure reducer RDP : Hydraulic unit and components - Quiri

Type RDP 3.1 R :

Pressure reducer developed for low pressure applications in ranges from 15 to 130 bars.
The bodies of these reducers can be placed in place of most installations, even from other brands.

Pressure reducer RDP : Hydraulic unit and components - Quiri - 2
Type Reference
Pressure

range

Max flow

rate

bar l/min
RDP 3 1 T A 66 277 15 to 130 12
2 A 66 325 20 to 200
3 A 66 324 30 to 300
RDP 3 1 P A 66 323 15 to 130 12
2 A 66 288 20 to 200
3 A 66 322 30 to 300
RDP 3 1 C A 66 321 15 to 130 12
2 A 66 320 20 to 200
3 A 66 319 30 to 300
RDP 3 1 R 354 008/400 15 to 130 12