close pdf print video more home burger search arrow

Hydraulic cylinders and components, hydraulic systems, gas springs & shell and tube heat exchangers : Quiri

Check valve RH

Mounting on plate or in line

Operating principle

The check valve allows free flow from B to A and prevents flow from A to B. A to B is opened by hydraulic control Z. The pipe L is provided to drain any leaks.

Print this sheet
Check valve RH : Hydraulic unit and components - Quiri
Port pressure
Type Reference
A B Z L Max flow

rate

Weight

 

Pressure ratio:

(Control/A)

bar bar bar bar l/min Kg
RH 1 A 64 383 700 700 700 15 0,40 1/2

View similar products